28 May 2003

 

LENA State Log

 

 

 Time (UT)                               Event                                                                  LENA Time (UT)*

00 085 21:30:34 (25 Mar 00)            launch

087 06:00 (27 Mar 00)            instrument on liveness test

18:00                           instrument off

112 16:13 (21 Apr 00)            instrument on

115 14:40 (24 Apr 00)            set overcount threshold to 2AF8

14:52                           HVPS unsafed

14:53                           normal mode implemented

15:03                           voltage thresholds to AA AA 74 74 51

15:04                           current thresholds to FFx5

15:14                           start/stop CFDs to level 8

15:19                           start/stop MCPs to level 0

15:30                           start/stop MCPs enabled

15:37                           start/stop MCPs to level 20

15:44                           start/stop MCPs to level 40

15:51                           start/stop MCPs to level 50

16:01                           start/stop MCPs to level 60

16:08                           voltage thresholds to D5 D5 91 91 73

16:09                           start/stop MCPs to level 70

16:17                           start/stop MCPs to level 80

16:31                           start/stop MCPs to level 88

16:42                           start/stop MCPs to level 90

116 03:20 (25 Apr 00)            overcount pushes start/stop MCPs to level 7C

16:28-18:36             overcount pushes start/stop MCPs to level 72

119 12:12 (28 Apr 00)            start/stop MCPs to level 80

12:19                           start/stop MCPs to level 88

12:23                           start/stop MCPs to level 90

12:40                           coll plus/coll minus to level 0

12:53                           coll plus/coll minus enabled

13:00                           coll plus/coll minus to level 10 (+/- 2.4)

13:13                           coll plus/coll minus to level 20 (+/- 2.7)

13:27                           coll plus/coll minus to level 30 (+/- 3.2)

13:46                           coll plus/coll minus to level 40 (+/- 3.6)

13:59                           coll plus/coll minus to level 50 (+/- 4.1)

14:07                           coll plus/coll minus to level 60 (+/- 4.4)

14:24-18:14            overcount pushes start/stop MCPs to level 72

                                    and coll plus/minus to level 0

19:07                           set overcount threshold to FFFF (disabled)

19:11                           start/stop MCPs to level 80

19:19                           start/stop MCPs to level 88

19:29                           start/stop MCPs to level 90

120 18:42 (29 Apr 00)            start/stop CFDs to level 2/6 (Denver levels)

122 23:51 (1 May 00)            stop MCP to level 50                                               23:52:29

23:59                           stop MCP to level 60                                               00:00:14

123 00:06 (2 May 00)            stop MCP to level 70                                               

00:17                           stop MCP to level 80

124 01:40 (3 May 00)            optics to level 0

01:48                           optics enabled                                                          01:50:01

02:08                           optics to level 10                                                     02:10:00

02:21                           optics to level 20                                                     02:24:00

02:38                           optics to level 30                                                     02:39:58

03:00                           optics to level 40                                                     03:01:57

03:14                           optics to level 50                                                     03:15:56

03:32                           voltage thresholds to D5 D5 91 91 86                   

03:45                           optics to level 60                                                     03:45:54

04:13                           optics to level 68                                                     04:13:52

04:33                           voltage thresholds to D5 D5 91 91 97                    

04:38                           optics to level 70                                                      04:39:51

04:53                           optics to level 78                                                      04:53:50

126 21:13 (5 May 00)            set position sensing to low gain

148 11:07 (27 May 00)            set steering controller to level 0

11:13                           enabled steering controller stepping table

11:23                           disabled steering controller stepping table

11:33                           set steering controller to level 20                             11:33:56

11:43                           set steering controller to level 40                             11:43:58

12:05                           set steering controller to level 60                             12:06:02

12:25                           set steering controller to level 80                             12:26:07

155 02:52 (3 June 00)            redefine mass 1 bin to 27-2B (bin 156-175)

02:54                           stop MCP to level 90

03:53                           coll plus/coll minus to level 10 (+/- 2.4)                 03:54:40

04:07                           coll plus/coll minus to level 20 (+/- 2.7)                 04:08:42

04:22                           coll plus/coll minus to level 30 (+/- 3.2)                 04:22:45

04:37                           coll plus/coll minus to level 40 (+/- 3.6)                 04:36:48

04:52                           coll plus/coll minus to level 50 (+/- 4.1)                 04:52:51

05:10                           coll plus/coll minus to level 60 (+/- 4.4)                 05:10:53

10:10                           *** start of uploaded commanding ***

16:40                           *** all S/I's including LENA safed ***

156 18:33 (4 June 00)            instrument on

18:56                           HVPS unsafed

18:57                           normal mode implemented

19:02                           voltage thresholds to AA AA 74 74 51

                                    current thresholds to FFx5

                                    MCP's, optics and coll to level 0

19:08                           MCP's, optics and coll enabled

19:43                           set overcount threshold to FFFF (disabled)

19:51                           start/stop CFDs to level 2/6 (Denver levels)

19:53                           set position sensing to low gain

19:53                           set steering controller to level 0

19:55                           redefine mass 1 bin to 27-2B (bin 156-175)

20:03                           MCP's to level 20, coll/optics to level 10                20:05:04

20:11                           MCP's to level 40                                                     20:11:05

            20:22                           MCP's to level 50                                                     20:23:08

    157  18:06 (5 June 00)        coll/optics to level 20                                               18:06:56

            18:12                           MCP’s to level 60                                                    18:12:57

            18:21                           voltage thresholds to D5 D5 91 91 73                     18:22:59

                                                MCP’s to level 70, coll/optics to level 30               

            18:42                           MCP’s to level 80, coll/optics to level 40               18:43:03

            18:53                           start MCP to level 88                                               18:55:05

            19:00                           coll/optics to level 50                                               19:01:07

            19:06                           start MCP to level 90                                               19:07:08

    158  22:29 (6 June 00)        voltage thresholds to D5 D5 91 91 86

            22:29                           optics to level 60                                                      22:30:13

            22:39                           optics to level 69, coll to level 60                            22:40:15

            22:48                           voltage thresholds to D5 D5 91 91 97

            22:49                           optics to level 70                                                      22:50:17

            23:24                           optics to level 78                                                      23:34:27

            23:40                           stop MCP to level 88                                               23:40:28

            23:47                           stop MCP to level 90                                               23:48:29

    159  10:10 (7 June 00)        ** start of uploaded commanding **

    161  22:00 (9 June 00)         redefine mass bin 1 to 0-7F and mass

                                                 bin 2 to 80-FF

            22:01                           stop MCP to level 90

    169  12:10 (17 June 00)      ** all S/I’s including LENA safed **                     12:11:28

    172  02:27 (20 June 00)      instrument on

            02:27                           HVPS unsafed

            02:27                           normal mode implemented

            02:32                           voltage thresholds to AA AA 74 74 51

                                                current thresholds to FFx5

                                                MCP’s, optics and coll to level 0

            02:38                           MCP’s, optics and coll enabled                               02:39:43

    173  03:01 (21 June 00)      MCP’s to level 20,coll/optics to level 10                03:02:25

            03:07                           set overcound threshold to level FFFF (disabled)  

            03:08                           start/stop CFDs to level 2/6 (Denver levels)           03:10:35

            03:10                           set position sensing gain to low

            03:15                           MCP’s to level 40                                                     03:16:43

            03:24                           MCP’s to level 50                                                     03:24:53

            03:30                           coll/optics to level 20                                                03:31:00

            03:37                           MCP’s to level 60                                                     03:39:11

            03:45                           voltage thresholds to D5 D5 91 91 73                      03:47:21

                                                MCP’s to level 70, coll/optics to level 30

            03:53                           MCP’s to level 80, coll/optics to level 40                03:55:31

            04:01                           MCP’s to level 88                                                    04:01:39

            04:11                           coll/optics to level 50                                               04:11:52

            04:17                           MCP’s to level 90                                                    04:17:59

            04:23                           voltage thresholds to D5 Dd5 91 91 86

            04:29                           optics to level 68, coll to level 60                            04:30:15

04:34                           voltage thresholds to D5 D5 91 91 97                     04:34:20

                                    optics to level 70

04:38                           optics to level 78                                                      04:38:26

04:43                           optics to level 80 (12.1 kV)                                     04:44:33

15:46                           *** start of uploaded commanding ***

176 05:14 (24 June 00)            HVPS error flag reset (no impact error)

180 19:55 (28 June 00)            HVPS error flag reset (no impact error)

195 15:20 (13 July 00)            HVPS error flag reset (no impact error)                  

196 16:50 (14 July 00)            coll plus/coll minus lowered to level 00 due to       16:52:35

                                            overcount, optics lowered to level 76 (11.3 kV)

                                            due to overcount

213 00:28 (31 July 00)            uploaded LENA FSW V3.3 to CIDP

00:49                           optics to level 33                                                      00:50:47

00:53                           global off (all supplies to 00, disabled and safed)   00:54:52

00:58                           instrument reset sent

01:35                           instrument reset sent

02:06                           uploaded LENA FSW V3.3 to CIDP

                                    (reversing header byte order)

02:23                           instrument reset sent

02:42                           CIDP commanded LENA off

02:44                           instrument on

03:00                           uploaded LENA FSW V3.3 to CIDP

03:17                           CIDP commanded LENA off

03:20                           instrument on

03:37                           uploaded LENA FSW V3.3 to CIDP

                                    (using old header byte order)

03:55                           instrument reset sent

0413                            HVPS unsafed

                                    normal mode implemented

04:19                           voltage thresholds to AA AA 74 74 51

                                    current thresholds to FFx5

04:20                           MCP's, optics and coll to level 0

04:25                           MCP's, optics and coll enabled                                     04:27:27

04:31                           MCP's to level 20, optics to level 10                             04:31:33

04:36                           MCP's to level 40                                                          04:37:40

04:40                           MCP's to level 50                                                          04:41:46

04:53                           optics to level 20                                                           04:54:02

04:56                           MCP's to level 60                                                          04:58:07

05:01                           voltage thresholds to D5 D5 91 91 73

05:02                           MCP's to level 70, optics to level 30                             05:04:15

05:07                           MCP's to level 80, optics to level 40                             05:08:20

05:12                           MCP's to level 88                                                          05:12:25

05:17                           optics to level 50                                                            05:18:33

05:21                           MCP's to level 90                                                            05:22:38

05:25                           voltage thresholds to D5 D5 91 91 86

05:26                           optics to level 60                                                             05:26:44

05:29                           optics to level 68                                                             05:30:49

05:33                           voltage thresholds to D5 D5 91 91 97

05:34                           optics to level 70                                                             05:34:54

05:37                           optics to level 78                                                             05:38:59

05:42                           optics to level 80                                                             05:43:05

05:47                           collimators enabled (+/- 1.8)                                          05:49:13

05:56                           coll to level 10 (+/- 2.4)                                                  05:57:23

06:00                           coll to level 20 (+/- 2.7)                                                  06:01:28

06:04                           coll to level 30 (+/- 3.2)                                                  06:05:33

06:08                           coll to level 40 (+/- 3.6)                                                  06:09:39

06:12                           coll to level 50 (+/- 4.1)                                                  06:13:44

06:17                           coll to level 60 (+/- 4.4)                                                  06:17:49

06:18                           *** end of uploaded commanding *** (deleted queue)

06:21                           saved MCP stop supply state

06:27                           set overcount threshold to level 0023 (296 kHz)

06:33                           set overcount threshold to level 0017 (194 kHz)

06:37                           enabled stop MCP overcount auto restore

214 18:52 (1 Aug 00)            set overcount threshold to level 000B (93 kHz)

18:56                           set memory read to 05 A0 01 00 (engineering data)

230 20:09 (17 Aug 00)            set memory read to 20 2D 01 00 (A111 amplitude data)

244 14:45 (31 Aug 00)            disabled ramping back up to nominal voltage

14:46                              MCP's to level 0                                                              14:47:40                                                       

14:51                           MCP's disabled                                                                14:53:48

15:05                           MCP's enabled                                                                 15:06:04

15:13                           MCP's to level 40                                                            15:14:14

15:35                           MCP's to level 70                                                            15:36:42

15:43                           MCP's to level 80                                                            15:44:52

15:50                           MCP's to level 90                                                            15:51:00

                                    system restore enabled

15:55                           stop MCP to level 80                                                       15:57:08

15:57                           start/stop CFDs to level 2/6 (Denver levels)

22:26                           optics to level 33

22:31                           system restore disabled                                                    22:27:55

22:32                           high voltage global off

22:41                           instrument off

22:49                           instrument on

23:09                           high voltage global unsafe

23:18                           voltage thresholds to AA AA 74 74 51

23:20                           current thresholds to FFx5

23:21                           MCP's to level 0                                                             

23:26                           MCP's enabled                                                                 23:27:09  

23:31                           MCP's to level 20                                                             23:31:14

23:35                           MCP's to level 40                                                             23:35:19

23:41                           MCP's to level 50                                                             23:41:27

23:48                           MCP's to level 60                                                             23:49:37

23:53                           MCP's to level 70                                                             23:53:43

23:57                           MCP's to level 80                                                             23:57:48

245 00:06 (1 Sept 00)            MCP's to level 88                                                             00:05:58

00:13                           start MCP to level 90                                                        00:14:08

00:27                           start CFD to level 3                                                           00:28:27

00:35                           start CFD to level 4                                                           00:36:37

00:42                           start CFD to level 6                                                           00:42:45

00:47                           start/stop CFDs to level  10/4                                           00:48:52

00:54                           start CFD to level 12                                                         00:55:00

00:59                           start CFD to level 11                                                         01:01:08

            01:11                           start CFD to level 9

            01:19                           optics enabled                                                                                  

            01:24                           collimators enabled (no change in rate)                            01:25:39

            01:29                           optics to level 10                                                               01:29:44

            01:35                           optics to level 20                                                               01:35:52

            01:41                           voltage thresholds to D5 D5 91 91 73                              01:42:00

                                                optics to level 30

            01:47                           optics to level 40                                                               01:48:07

            01:56                           optics to level 50                                                               01:56:18

            02:03                           voltage thresholds to D5 D5 91 91 86                              02:04:28

                                                optics to level 60

            02:11                           optics to level 68                                                               02:12:39

            02:16                           voltage thresholds to D5 D5 91 91 97                              02:16:44

                                                optics to level 70

            02:21                           optics to level 78                                                               02:22:52

            02:28                           MCP’s to level 94                                                             02:28:59

            02:49                           MCP’s to level 90                                                             02:49:25

            02:56                           MCP’s to level 88                                                             02:57:36

            03:14                           coll to level 10                                                                  03:13:57

            03:32                           set overcount threshold to 000C

            03:33                           saved MCP stop supply state

                                                enabled stop MCP overcount auto restore

            03:37                           saved MCP stop supply state

            03:39                           MCP’s to level 98                                                             03:40:30

            03:45                           coll to level 20                                                                  03:46:38

            03:52                           coll to level 30                                                                  03:52:46

            03:58                           coll to level 40                                                                  03:58:54

            04:04                           coll to level 50                                                                  04:05:01

            04:09                           coll to level 60                                                                  04:09:07

            04:20                           MCP’s to level 96                                                             04:21:22

     251 14:23 (7 Sept 00)        disabled ramping back up to nominal voltage

            14:25                           collimators enabled

            14:35                           collimators disabled (neg)

            14:51                           collimators disabled (pos)

            14:57                           collimators enabled

            15:10                           stop CFDs to level 6

            15:18                           MCP’s to level 90                                                            15:18:46

            15:29                           start CFDs to level 2

            15:37                           start CFDs to level 9

            15:57                           voltage thresholds to A0 D5 91 91 97

            15:58                           current thresholds to 82 FFx4

            16:15                           saved MCP stop supply state

            16:16                           enabled stop MCP overcount auto restore

            16:25                           voltage thresholds to A0 D5 91 30 97

                                                current thresholds to 82 FF FF C0 FF                  

    253  20:04 (9 Sept 00)        set overcount threshold to 000E

            20:15                           MCP’s enabled                                                                 20:17:29

            20:39                           MCP’s to level 20                                                             20:39:57

            20:45                           MCP’s to level 40                                                             20:46:05

            20:53                           MCP’s to level 60                                                             20:54:15

            21:06                           MCP’s to level 80                                                             21:06:31

            21:12                           MCP’s to level 88                                                             21:14:40

            21:22                           MCP’s to level 90                                                             21:22:51

           21:46                            start CFD’s

    258 13:34 (14 Sept 00)       HVPS error flag reset (no impact error)

    263 11:28 (19 Sept 00)       HVPS error flag reset (no impact error)

           20:26                             MCP’s to level 0

           20:35                             MCP’s enabled                                                                20:37:58

           20:40                             MCP’s to level 40                                                            20:42:03

           20:44                             MCP’s to level 90                                                            20:46:07

   266  19:15 (22 Sept 00)        HVPS error flag reset (no impact error)

           19:16                             MCP’s to level 0

           19:21                             MCP’s enabled                                                                19:23:24

           19:26                             MCP’s to level 40                                                            19:27:29

           19:29                             MCP’s to level 90                                                            19:31:33

    269 18:38 (25 Sept 00)        HVPS error flag reset (no impact error)

           18:38                             MCP’s to level 0

           18:46                             MCP’s enabled

           19:01                             MCP’s to level 40                                                            19:03:27

           19:06                             MCP’s to level 90                                                            19:07:31

   278  17:04 (4 Oct 00)           uploaded LENA FSW V3.4 to CIDP 

           17:24                             instrument reset sent

           17:42                             HVPS unsafed

           17:50                             voltage thresholds to AA AA 74 74 51

           17:52                             current thresholds set to FFx5

           17:54                             MCP’s to level 0

           18:10                             MCP’s enabled                                                                18:11:56

           18:15                             MCP’s to level 40                                                            18:16:01

           18:21                             MCP’s to level 80                                                            18:22:08

           18:42                             MCP’s to level A0                                                           18:42:33

           18:43                             MCP’s to level 90                                                            18:44:36

           18:49                             start CFDs to level 11d    

           18:53                             optics enabled                                                                  18:54:48

           18:55                             deleting LENA queue

           19:02                             optics to level 20                                                              19:02:58

           19:06                             optics to level 40                                                              19:07:03

           19:09                             optics to level 50                                                              19:11:08

           19:15                             optics to level 60                                                              19:17:15

           19:26                             optics to level 70                                                              19:27:28

           19:31                             optics to level 78                                                              19:31:33

           19:45                             collimators enabled (neg)                                                19:47:53

           19:55                             collimators enabled (pos)                                                 19:56:03

           20:02                             collimators disabled (pos)

           20:03                             reset error flags

           20:10                             coll to level 10                                                                 20:12:24

           20:22                             coll to level 20                                                                 20:22:36

           20:30                             collimators disabled (neg)

           20:43                              coll to level 0

           20:46                              collimators enabled                                                         20:47:06

           20:50                              current threshold set to 82 76 FF C0 6E

           20:52                              saved MCP stop supply state

           20:54                              enabled stop MCP overcount auto restored

    280 19:30 (6 Oct 00)            MCP’s disabled                                                              19:31:11

           19:34                              MCP’s to level 0

           19:35                              disabled ramping back up to nominal voltage

           19:48                              MCP’s to level 0

           19:49                              saved MCP stop supply state

           19:56                              MCP’s enabled                                                               19:57:44

           20:00                              MCP’s to level 40H                                                        20:01:48

           20:04                              MCP’s to level 80H                                                        20:05:54

           20:08                              MCP’s to level A0                                                          20:09:59

           20:09                              MCP’s to level 90H                                                        20:09:59

           20:18                              collimators enabled                                                         20:20:11

           20:23                              saved MCP stop supply state

           20:27                              enabled stop MCP overcount auto restore

   283 18:15 (9 Oct 00)              reset error flags

          18:19                               set overcount threshold to 0003

          18:23                               MCP’s to level 0

          18:27                               MCP’s enabled                                                               18:29:32                                      

          18:32                               MCP’s to level 40H                                                        18:33:37

          18:48                               MCP’s to level 80H                                                        18:47:54

   284 18:13 (10 Oct 00)            reset error flags

          18:17                               set overcount threshold to 0006

          19:03                               MCP’s to level 90H                                                        19:06:15

          19:04                               MCP’s to level A0                                                          19:06:15

   292 22:38 (18 Oct 00)            reset error flags

          22:39                               MCP’s to level 40H                                                            

          22:45                               MCP’s to level 0                                                           

          22:48                               MCP’s enabled                                                               22:49:58

          22:52                               MCP’s to level 40H                                                        22:54:03

          22:58                               MCP’s to level 80H                                                        23:00:10

          23:02                               MCP’s to level 90H                                                        23:04:15

          23:06                               write parameters to memory

  293 18:52 (19 Oct 00)            enable transmission of ROI sci packet

                                                  Enable transmission of valid event by sector sci packet

          18:53                               Enable transmission of monitor hk packet

   322 16:51 (17 Nov 00)          uploaded LENA FSW V3.5 to CIDP 

          17:07                               uploaded LENA FSW V3.5 to CIDP 

          17:16                               uploaded LENA FSW V3.5 to CIDP 

          17:38                               instrument reset sent

          17:58                               HVPS unsafed

          18:04                               voltage threshold set to AA AA 74 74 51

          18:05                               current threshold set to FFx5

          18:07                               MCP’s to level 0

          18:13                               set overcount threshold to 000C

          18:15                               MCP’s enabled                                                               18:15:24

          18:19                               MCP’s to level 40H                                                        18:19:30

          18:24                               MCP’s to level 80H                                                        18:25:38

          18:28                               voltage threshold set to D5 D5 91 91 73

          18:33                               MCP’s to level A0                                                          18:33:48

          18:36                               start CFDs to level 11

          18:39                               current threshold set to  82 76 FF C0 6E

          18:42                               optics enabled                                                                 18:44:02

          18:47                               optics to level 20H                                                          18:48:07

          18:50                               optics to level 40H                                                          18:52:13

          18:55                               optics to level 50H                                                          18:56:18

          19:03                               optics to level 60H                                                          19:04:29

          19:07                               voltage threshold set to D5 D5 91 91 97

          19:11                               optics to level 70H                                                          19:12:40

          19:15                               optics to level 78H                                                          19:16:45

          19:28                               collimator enabled                                                          19:29:01

          19:33                               saved MCP stop supply state

   335 20:55 (30 Nov 00)           write parameters to memory

                                                  write parameters to memory

          20:56                               write parameters to memory

   339 00:44 (4 Dec 00)             enabled steering control scanning

                                                  enabled stop MCP overcount auto restore

          14:12                               disabled LENA autonomous capabilities

   341 22:33 (6 Dec 00)             enabled stop MCP overcount auto restore

          22:38                               set overcount threshold to 0009

   342 19:48 (7 Dec 00)             reset error flags

   348 23:19 (13 Dec 00)          HVPS unsafed

          23:31                              voltage threshold set to AA AA 74 74 51

          23:33                              current threshold set to FFx5

          23:35                              MCP’s to level 0

          23:43                              set overcount threshold to 0009

          23:54                              MCP’s enabled                                                                23:55:11

          23:57                              MCP’s to level 40H                                                         23:59:17

   349 00:10 (14 Dec 00)          MCP’s to level 80H                                                         00:11:33

          00:15                              voltage threshold to D5 D5 91 91 73

          00:16                              MCP’s to level A0                                                           00:17:41

          00:16                              MCP’s to level 90H                                                         00:17:41

          00:32                              optics enabled                                                                  00:34:03

          00:39                              optics to level 20H                                                           00:40:12

          00:49                              optics to level 40H                                                           00:50:25

          00:56                              optics to level 50H                                                           00:56:33

          00:59                              optics to level 60H                                                           01:00:39

          01:01                              voltage threshold to D5 D5 91 91 97

          01:04                              optics to level 70H                                                           01:04:44

          01:10                              optics to level 78H                                                           01:10:53

                                                 collimators enabled

          01:11                              saved MCP stop supply state

          01:29                              write parameters to memory     

          01:31                              write parameters to memory                                    

          01:33                              write parameters to memory                                    

   011 23:51 (11 Jan 01)           instrument on                                                                   23:54:45

   012 00:07 (12 Jan 01)           HVPS unsafed

          00:19                              voltage threshold to AA AA 74 74 51

          00:20                              current threshold to FFx5

          00:21                              MCP’s to level 0

          00:32                              set overcount threshold to 0009 (75 kHz)

          00:36                              MCP’s enabled

          00:37                              MCP’s to level 40H                                                         00:39:32

          00:49                              MCP’s to level 80H                                                         00:51:48

          00:50                              voltage threshold to D5 D5 91 91 73

          00:56                              MCP’s to level A0                                                           00:57:57

                                                 MCP’s to level 90

          01:08                              start CFDs to level 11

          01:09                              current threshold to 82 76 FF C0 6E

          01:09                              optics enabled                                                                  01:12:17

          01:18                              optics to level 20H                                                          01:20:28

          01:23                              optics to level 40H                                                           01:26:36

          01:30                              optics to level 50H                                                           01:32:44

          01:34                              optics to level 60H                                                           01:36:50

          01:35                              voltage threshold to D5 D4 91 91 97

          01:41                              optics to level 70H                                                           01:42:58

          01:46                              optics to level 78H

          01:56                              optics enabled                                                                  01:57:18

                                                 optics to level 20H

          02:01                              optics to level 40H                                                          02:03:26

          02:05                              optics to level 50H                                                          02:07:32

          02:09                              optics to level 60H                                                          02:11:37

          02:13                              optics to level 70H                                                          02:15:43

          02:20                              collimator enabled                                                           02:21:51

                                                 saved MCP stop supply state

          02:35                              write parameters to memory

          02:37                              write parameters to memory

          02:37                              write parameters to memory

         02:38                               enapled stop MCP overcount auto restore

 016  19:48 (16 Jan 01)            defined start of TOF to 26

         19:49                               defined start of TOF to 30

                                                 defined start of TOF to 64

         19:50                               defined start of TOF to 0FA

         19:54                               defined ROI  Region is 252 - 260 (3F*4 start bin,

                                                 width =8, all energy, polar & spin sectors).

         19:56                               enabled ROI packets 00

         22:05                               defined start of TOF to 30

                                                 defined start of TOF to 64

         22:06                               defined start of TOF to 26

                                                 defined start of TOF to 30

         22:07                               defined stop of TOF to OFA

 023  20:41 (23 Jan 01)            uploaded LENA FSW V3.6 to CIDP (no-reply)

         20:55                               uploaded LENA FSW V3.6 to CIDP 

         21:25                               instrument reset sent

         21:47                               HVPS unsafed

         21:49                               voltage threshold to AA AA 74 74 51

         21:50                               MCP’s to level 0

         21:51                               set overcount threshold to 0009

         21:55                               MCP’s enabled                                                                21:55:53

                                                 MCP’s to level 40H                 

         22:01                               MCP’s to level 80H                                                         22:02:02

                                                 voltage threshold to D5 D5 91 91 73

         22:05                               MCP’s to level A0                                                           22:06:07

                                                 MCP’s to level 90H

         22:09                               optics enabled                                                                  22:10:13

         22:13                               optics to level 20H                                                           22:14:19

         22:17                               optics to level 40H                                                           22:18:24

         22:21                               optics to level 50H                                                           22:22:30

         22:26                               optics to level 60H                                                           22:26:35

                                                 voltage threshold to D5 D5 91 91 97

         22:32                               optics to level 70H                                                           22:32:44

         22:36                               optics to level 78H                                                           22:36:49

         22:41                               collimators enabled (neg)                                                22:40:55

                                                 saved MCP stop supply state

                                               defined ROI

                                               enabled ROI packets 1

                                               enabled stop MCP overcount auto restore

   024 20:53 (24 Jan 01)         MCP’s to level 80H

          21:01                            reset error flags

   025 16:04 (25 Jan 01)         MCP’s to level 80H

   026 18:04 (26 Jan 01)         write parameters to memory

          18:05                            reset error flags

   040 20:45 (9 Feb 01)          write parameters to memory

         20:46                             write parameters to memory

   046 19:41 (15 Feb 01)        write parameters to memory

          19:42                            write parameters to memory

          19:43                            reset error flags

   068 03:15  (12 Mar 01)       write parameters to memory A9DD

          03:16                            write parameters to memory A9DF

          03:17                             reset error flags

 

“ISN MODE” TEST  

   316 01:37:28 (12 Nov 01)  Disable steering supply scan

          01:37:28                       Steering scan table is defined by array P[15] – P[0].  Steering                                                 

                                               supply steps through 1 command P[n] per spin.

          01:37:28                       Enable steering supply scan

          05:37:28                       Disable steering supply scan

 

Leonids “Chicken Mode”  

  322  04:00:00 (18 Nov 01)   Reset error flags

          04:00:00                       Disable auto restore

          04:00:00                       Disable collimators

          23:59:00                       Enable auto restore

 

326    02:55 – 16:03 (22 Nov 01)                

                                              Unrecoverable Data loss due to loss of command link to the                 

                                              spacecraft during MMM overwrite fix procedure

 

 361  (27 Dec 01)                   Spin-phase freewheeling anomaly

                                               corrected 22:34, 28 Dec 01

 

233      19:42:43 (21 Aug 02)  MCP Start HVPS to level A0H

233      19:43:31                       MCP Stop HVPS to level 90H

233   19:44:17                       Enable LENA Stop MCP HVPS auto-restore

 

  241   13:50:01 (29 Aug 02)   defined start TOF to 10H

 

311   14:18:00 (7 Nov 02)