28 May 2003

 

LENA State Log

 

 

 Time (UT)                               Event                                                                  LENA Time (UT)*

00 085 21:30:34 (25 Mar 00)            launch

087 06:00 (27 Mar 00)            instrument on liveness test

18:00                           instrument off

112 16:13 (21 Apr 00)            instrument on

115 14:40 (24 Apr 00)            set overcount threshold to 2AF8

14:52                           HVPS unsafed

14:53                           normal mode implemented

15:03                           voltage thresholds to AA AA 74 74 51

15:04                           current thresholds to FFx5

15:14                           start/stop CFDs to level 8

15:19                           start/stop MCPs to level 0

15:30                           start/stop MCPs enabled

15:37                           start/stop MCPs to level 20

15:44                           start/stop MCPs to level 40

15:51                           start/stop MCPs to level 50

16:01                           start/stop MCPs to level 60

16:08                           voltage thresholds to D5 D5 91 91 73

16:09                           start/stop MCPs to level 70

16:17                           start/stop MCPs to level 80

16:31                           start/stop MCPs to level 88

16:42                           start/stop MCPs to level 90

116 03:20 (25 Apr 00)            overcount pushes start/stop MCPs to level 7C

16:28-18:36             overcount pushes start/stop MCPs to level 72

119 12:12 (28 Apr 00)            start/stop MCPs to level 80

12:19                           start/stop MCPs to level 88

12:23                           start/stop MCPs to level 90

12:40                           coll plus/coll minus to level 0

12:53                           coll plus/coll minus enabled

13:00                           coll plus/coll minus to level 10 (+/- 2.4)

13:13                           coll plus/coll minus to level 20 (+/- 2.7)

13:27                           coll plus/coll minus to level 30 (+/- 3.2)

13:46                           coll plus/coll minus to level 40 (+/- 3.6)

13:59                           coll plus/coll minus to level 50 (+/- 4.1)

14:07                           coll plus/coll minus to level 60 (+/- 4.4)

14:24-18:14            overcount pushes start/stop MCPs to level 72

                                    and coll plus/minus to level 0

19:07                           set overcount threshold to FFFF (disabled)

19:11                           start/stop MCPs to level 80

19:19                           start/stop MCPs to level 88

19:29                           start/stop MCPs to level 90

120 18:42 (29 Apr 00)            start/stop CFDs to level 2/6 (Denver levels)

122 23:51 (1 May 00)            stop MCP to level 50                                               23:52:29

23:59                           stop MCP to level 60                                               00:00:14

123 00:06 (2 May 00)            stop MCP to level 70                                               

00:17                           stop MCP to level 80

124 01:40 (3 May 00)            optics to level 0

01:48                           optics enabled                                                          01:50:01

02:08                           optics to level 10                                                     02:10:00

02:21                           optics to level 20                                                     02:24:00

02:38                           optics to level 30                                                     02:39:58

03:00                           optics to level 40                                                     03:01:57

03:14                           optics to level 50                                                     03:15:56

03:32                           voltage thresholds to D5 D5 91 91 86                   

03:45                           optics to level 60                                                     03:45:54

04:13                           optics to level 68                                                     04:13:52

04:33                           voltage thresholds to D5 D5 91 91 97                    

04:38                           optics to level 70                                                      04:39:51

04:53                           optics to level 78                                                      04:53:50

126 21:13 (5 May 00)            set position sensing to low gain

148 11:07 (27 May 00)            set steering controller to level 0

11:13                           enabled steering controller stepping table

11:23                           disabled steering controller stepping table

11:33                           set steering controller to level 20                             11:33:56

11:43                           set steering controller to level 40                             11:43:58

12:05                           set steering controller to level 60                             12:06:02

12:25                           set steering controller to level 80                             12:26:07

155 02:52 (3 June 00)            redefine mass 1 bin to 27-2B (bin 156-175)

02:54                           stop MCP to level 90

03:53                           coll plus/coll minus to level 10 (+/- 2.4)                 03:54:40

04:07                           coll plus/coll minus to level 20 (+/- 2.7)                 04:08:42

04:22                           coll plus/coll minus to level 30 (+/- 3.2)                 04:22:45

04:37                           coll plus/coll minus to level 40 (+/- 3.6)                 04:36:48

04:52                           coll plus/coll minus to level 50 (+/- 4.1)                 04:52:51

05:10                           coll plus/coll minus to level 60 (+/- 4.4)                 05:10:53

10:10                           *** start of uploaded commanding ***

16:40                           *** all S/I's including LENA safed ***

156 18:33 (4 June 00)            instrument on

18:56                           HVPS unsafed

18:57                           normal mode implemented

19:02                           voltage thresholds to AA AA 74 74 51

                                    current thresholds to FFx5

                                    MCP's, optics and coll to level 0

19:08                           MCP's, optics and coll enabled

19:43                           set overcount threshold to FFFF (disabled)

19:51                           start/stop CFDs to level 2/6 (Denver levels)

19:53                           set position sensing to low gain

19:53                           set steering controller to level 0

19:55                           redefine mass 1 bin to 27-2B (bin 156-175)

20:03                           MCP's to level 20, coll/optics to level 10                20:05:04

20:11                           MCP's to level 40                                                     20:11:05

            20:22                           MCP's to level 50                                                     20:23:08

    157  18:06 (5 June 00)        coll/optics to level 20                                               18:06:56

            18:12                           MCP’s to level 60                                                    18:12:57

            18:21                           voltage thresholds to D5 D5 91 91 73                     18:22:59

                                                MCP’s to level 70, coll/optics to level 30               

            18:42                           MCP’s to level 80, coll/optics to level 40               18:43:03

            18:53                           start MCP to level 88                                               18:55:05

            19:00                           coll/optics to level 50                                               19:01:07

            19:06                           start MCP to level 90                                               19:07:08

    158  22:29 (6 June 00)        voltage thresholds to D5 D5 91 91 86

            22:29                           optics to level 60                                                      22:30:13

            22:39                           optics to level 69, coll to level 60                            22:40:15

            22:48                           voltage thresholds to D5 D5 91 91 97

            22:49                           optics to level 70                                                      22:50:17

            23:24                           optics to level 78                                                      23:34:27

            23:40                           stop MCP to level 88                                               23:40:28

            23:47                           stop MCP to level 90                                               23:48:29

    159  10:10 (7 June 00)        ** start of uploaded commanding **

    161  22:00 (9 June 00)         redefine mass bin 1 to 0-7F and mass

                                                 bin 2 to 80-FF

            22:01                           stop MCP to level 90

    169  12:10 (17 June 00)      ** all S/I’s including LENA safed **                     12:11:28

    172  02:27 (20 June 00)      instrument on

            02:27                           HVPS unsafed

            02:27                           normal mode implemented

            02:32                           voltage thresholds to AA AA 74 74 51

                                                current thresholds to FFx5

                                                MCP’s, optics and coll to level 0

            02:38                           MCP’s, optics and coll enabled                               02:39:43

    173  03:01 (21 June 00)      MCP’s to level 20,coll/optics to level 10                03:02:25

            03:07                           set overcound threshold to level FFFF (disabled)  

            03:08                           start/stop CFDs to level 2/6 (Denver levels)           03:10:35

            03:10                           set position sensing gain to low

            03:15                           MCP’s to level 40                                                     03:16:43

            03:24                           MCP’s to level 50                                                     03:24:53

            03:30                           coll/optics to level 20                                                03:31:00

            03:37                           MCP’s to level 60                                                     03:39:11

            03:45                           voltage thresholds to D5 D5 91 91 73                      03:47:21

                                                MCP’s to level 70, coll/optics to level 30

            03:53                           MCP’s to level 80, coll/optics to level 40                03:55:31

            04:01                           MCP’s to level 88                                                    04:01:39

            04:11                           coll/optics to level 50                                               04:11:52

            04:17                           MCP’s to level 90                                                    04:17:59

            04:23                           voltage thresholds to D5 Dd5 91 91 86

            04:29                           optics to level 68, coll to level 60                            04:30:15

04:34                           voltage thresholds to D5 D5 91 91 97                     04:34:20

                                    optics to level 70

04:38                           optics to level 78                                                      04:38:26

04:43                           optics to level 80 (12.1 kV)                                     04:44:33

15:46                           *** start of uploaded commanding ***

176 05:14 (24 June 00)            HVPS error flag reset (no impact error)

180 19:55 (28 June 00)            HVPS error flag reset (no impact error)

195 15:20 (13 July 00)            HVPS error flag reset (no impact error)                  

196 16:50 (14 July 00)            coll plus/coll minus lowered to level 00 due to       16:52:35

                                            overcount, optics lowered to level 76 (11.3 kV)

                                            due to overcount

213 00:28 (31 July 00)            uploaded LENA FSW V3.3 to CIDP

00:49                           optics to level 33                                                      00:50:47

00:53                           global off (all supplies to 00, disabled and safed)   00:54:52

00:58                           instrument reset sent

01:35                           instrument reset sent

02:06                           uploaded LENA FSW V3.3 to CIDP

                                    (reversing header byte order)

02:23                           instrument reset sent

02:42                           CIDP commanded LENA off

02:44                           instrument on

03:00                           uploaded LENA FSW V3.3 to CIDP

03:17                           CIDP commanded LENA off

03:20                           instrument on

03:37                           uploaded LENA FSW V3.3 to CIDP

                                    (using old header byte order)

03:55                           instrument reset sent

0413                            HVPS unsafed

                                    normal mode implemented

04:19                           voltage thresholds to AA AA 74 74 51

                                    current thresholds to FFx5

04:20                           MCP's, optics and coll to level 0

04:25                           MCP's, optics and coll enabled                                     04:27:27

04:31                           MCP's to level 20, optics to level 10                             04:31:33

04:36                           MCP's to level 40                                                          04:37:40

04:40                           MCP's to level 50                                                          04:41:46

04:53                           optics to level 20                                                           04:54:02

04:56                           MCP's to level 60                                                          04:58:07

05:01                           voltage thresholds to D5 D5 91 91 73

05:02                           MCP's to level 70, optics to level 30                             05:04:15

05:07                           MCP's to level 80, optics to level 40                             05:08:20

05:12                           MCP's to level 88                                                          05:12:25

05:17                           optics to level 50                                                            05:18:33

05:21                           MCP's to level 90                                                            05:22:38

05:25                           voltage thresholds to D5 D5 91 91 86

05:26                           optics to level 60                                                             05:26:44

05:29                           optics to level 68                                                             05:30:49

05:33                           voltage thresholds to D5 D5 91 91 97

05:34                           optics to level 70                                                             05:34:54

05:37                           optics to level 78                                                             05:38:59

05:42                           optics to level 80                                                             05:43:05

05:47                           collimators enabled (+/- 1.8)                                          05:49:13

05:56                           coll to level 10 (+/- 2.4)                                                  05:57:23

06:00                           coll to level 20 (+/- 2.7)                                                  06:01:28

06:04                           coll to level 30 (+/- 3.2)                                                  06:05:33

06:08                           coll to level 40 (+/- 3.6)                                                  06:09:39

06:12                           coll to level 50 (+/- 4.1)                                                  06:13:44

06:17                           coll to level 60 (+/- 4.4)                                                  06:17:49

06:18                           *** end of uploaded commanding *** (deleted queue)

06:21                           saved MCP stop supply state

06:27                           set overcount threshold to level 0023 (296 kHz)

06:33                           set overcount threshold to level 0017 (194 kHz)

06:37                           enabled stop MCP overcount auto restore

214 18:52 (1 Aug 00)            set overcount threshold to level 000B (93 kHz)

18:56                           set memory read to 05 A0 01 00 (engineering data)

230 20:09 (17 Aug 00)            set memory read to 20 2D 01 00 (A111 amplitude data)

244 14:45 (31 Aug 00)            disabled ramping back up to nominal voltage

14:46                              MCP's to level 0                                                              14:47:40                                                       

14:51                           MCP's disabled                                                                14:53:48

15:05                           MCP's enabled                                                                 15:06:04

15:13                           MCP's to level 40                                                            15:14:14

15:35                           MCP's to level 70                                                            15:36:42

15:43                           MCP's to level 80                                                            15:44:52

15:50                           MCP's to level 90                                                            15:51:00

                                    system restore enabled

15:55                           stop MCP to level 80                                                       15:57:08

15:57                           start/stop CFDs to level 2/6 (Denver levels)

22:26                           optics to level 33

22:31                           system restore disabled                                                    22:27:55

22:32                           high voltage global off

22:41                           instrument off

22:49                           instrument on

23:09                           high voltage global unsafe

23:18                           voltage thresholds to AA AA 74 74 51

23:20                           current thresholds to FFx5

23:21                           MCP's to level 0                                                             

23:26                           MCP's enabled                                                                 23:27:09  

23:31                           MCP's to level 20                                                             23:31:14

23:35                           MCP's to level 40                                                             23:35:19

23:41                           MCP's to level 50                                                             23:41:27

23:48                           MCP's to level 60                                                             23:49:37

23:53                           MCP's to level 70                                                             23:53:43

23:57                           MCP's to level 80                                                             23:57:48

245 00:06 (1 Sept 00)            MCP's to level 88                                                             00:05:58

00:13                           start MCP to level 90                                                        00:14:08

00:27                           start CFD to level 3                                                           00:28:27

00:35                           start CFD to level 4                                                           00:36:37

00:42                           start CFD to level 6                                                           00:42:45

00:47                           start/stop CFDs to level  10/4                                           00:48:52

00:54                           start CFD to level 12                                                         00:55:00

00:59                           start CFD to level 11                                                         01:01:08

            01:11                           start CFD to level 9

            01:19                           optics enabled                                                                                  

            01:24                           collimators enabled (no change in rate)                            01:25:39

            01:29                           optics to level 10                                                               01:29:44

            01:35                           optics to level 20                                                               01:35:52

            01:41                           voltage thresholds to D5 D5 91 91 73                              01:42:00

                                                optics to level 30

            01:47                           optics to level 40                                                               01:48:07

            01:56                           optics to level 50                                                               01:56:18

            02:03                           voltage thresholds to D5 D5 91 91 86                              02:04:28

                                                optics to level 60

            02:11                           optics to level 68                                                               02:12:39

            02:16                           voltage thresholds to D5 D5 91 91 97                              02:16:44

                                                optics to level 70

            02:21                           optics to level 78                                                               02:22:52

            02:28                           MCP’s to level 94                                                             02:28:59

            02:49                           MCP’s to level 90                                                             02:49:25

            02:56                           MCP’s to level 88                                                             02:57:36

            03:14                           coll to level 10                                                                  03:13:57

            03:32                           set overcount threshold to 000C

            03:33                           saved MCP stop supply state

                                                enabled stop MCP overcount auto restore

            03:37                           saved MCP stop supply state

            03:39                           MCP’s to level 98                                                             03:40:30

            03:45                           coll to level 20                                                                  03:46:38

            03:52                           coll to level 30                                                                  03:52:46

            03:58                           coll to level 40                                                                  03:58:54

            04:04                           coll to level 50                                                                  04:05:01

            04:09                           coll to level 60                                                                  04:09:07

            04:20                           MCP’s to level 96                                                             04:21:22

     251 14:23 (7 Sept 00)        disabled ramping back up to nominal voltage

            14:25                           collimators enabled

            14:35                           collimators disabled (neg)

            14:51                           collimators disabled (pos)

            14:57                           collimators enabled

            15:10                           stop CFDs to level 6

            15:18                           MCP’s to level 90                                                            15:18:46

            15:29                           start CFDs to level 2

            15:37                           start CFDs to level 9

            15:57                           voltage thresholds to A0 D5 91 91 97

            15:58                           current thresholds to 82 FFx4

            16:15                           saved MCP stop supply state

            16:16                           enabled stop MCP overcount auto restore

            16:25                           voltage thresholds to A0 D5 91 30 97

                                                current thresholds to 82 FF FF C0 FF                  

    253  20:04 (9 Sept 00)        set overcount threshold to 000E

            20:15                           MCP’s enabled                                                                 20:17:29

            20:39                           MCP’s to level 20                                                             20:39:57

            20:45                           MCP’s to level 40                                                             20:46:05

            20:53                           MCP’s to level 60                                                             20:54:15

            21:06                           MCP’s to level 80                                                             21:06:31

            21:12                           MCP’s to level 88                                                             21:14:40

            21:22                           MCP’s to level 90                                                             21:22:51

           21:46                            start CFD’s

    258 13:34 (14 Sept 00)       HVPS error flag reset (no impact error)

    263 11:28 (19 Sept 00)       HVPS error flag reset (no impact error)

           20:26                             MCP’s to level 0

           20:35                             MCP’s enabled                                                                20:37:58

           20:40                             MCP’s to level 40                                                            20:42:03

           20:44                             MCP’s to level 90                                                            20:46:07

   266  19:15 (22 Sept 00)        HVPS error flag reset (no impact error)

           19:16                             MCP’s to level 0

           19:21                             MCP’s enabled                                                                19:23:24

           19:26                             MCP’s to level 40                                                            19:27:29

           19:29                             MCP’s to level 90                                                            19:31:33

    269 18:38 (25 Sept 00)        HVPS error flag reset (no impact error)

           18:38                             MCP’s to level 0

           18:46                             MCP’s enabled

           19:01                             MCP’s to level 40                                                            19:03:27

           19:06                             MCP’s to level 90                                                            19:07:31

   278  17:04 (4 Oct 00)           uploaded LENA FSW V3.4 to CIDP 

           17:24                             instrument reset sent

           17:42                             HVPS unsafed

           17:50                             voltage thresholds to AA AA 74 74 51

           17:52                             current thresholds set to FFx5

           17:54                             MCP’s to level 0

           18:10                             MCP’s enabled                                                                18:11:56

           18:15                             MCP’s to level 40                                                            18:16:01

           18:21                             MCP’s to level 80                                                            18:22:08

           18:42                             MCP’s to level A0                                                           18:42:33

           18:43                             MCP’s to level 90                                                            18:44:36

           18:49                             start CFDs to level 11d    

           18:53                             optics enabled                                                                  18:54:48

           18:55                             deleting LENA queue

           19:02                             optics to level 20                                                              19:02:58

           19:06                             optics to level 40                                                              19:07:03

           19:09                             optics to level 50                                                              19:11:08

           19:15                             optics to level 60                                                              19:17:15

           19:26                             optics to level 70                                                              19:27:28

           19:31                             optics to level 78                                                              19:31:33

           19:45                             collimators enabled (neg)                                                19:47:53

           19:55                             collimators enabled (pos)                                                 19:56:03

           20:02                             collimators disabled (pos)

           20:03                             reset error flags

           20:10                             coll to level 10                                                                 20:12:24

           20:22                             coll to level 20                                                                 20:22:36

           20:30                             collimators disabled (neg)

           20:43                              coll to level 0

           20:46                              collimators enabled                                                         20:47:06

           20:50                              current threshold set to 82 76 FF C0 6E

           20:52                              saved MCP stop supply state

           20:54                              enabled stop MCP overcount auto restored

    280 19:30 (6 Oct 00)            MCP’s disabled                                                              19:31:11

           19:34                              MCP’s to level 0

           19:35                              disabled ramping back up to nominal voltage

           19:48                              MCP’s to level 0

           19:49                              saved MCP stop supply state

           19:56                              MCP’s enabled                                                               19:57:44

           20:00                              MCP’s to level 40H                                                        20:01:48

           20:04                              MCP’s to level 80H                                                        20:05:54

           20:08                              MCP’s to level A0                                                          20:09:59

           20:09                              MCP’s to level 90H                                                        20:09:59

           20:18                              collimators enabled                                                         20:20:11

           20:23                              saved MCP stop supply state

           20:27                              enabled stop MCP overcount auto restore

   283 18:15 (9 Oct 00)              reset error flags

          18:19                               set overcount threshold to 0003

          18:23                               MCP’s to level 0

          18:27                               MCP’s enabled                                                               18:29:32                                      

          18:32                               MCP’s to level 40H                                                        18:33:37

          18:48                               MCP’s to level 80H                                                        18:47:54

   284 18:13 (10 Oct 00)            reset error flags

          18:17                               set overcount threshold to 0006

          19:03                               MCP’s to level 90H                                                        19:06:15

          19:04                               MCP’s to level A0                                                          19:06:15

   292 22:38 (18 Oct 00)            reset error flags

          22:39                               MCP’s to level 40H                                                            

          22:45                               MCP’s to level 0                                                           

          22:48                               MCP’s enabled                                                               22:49:58

          22:52                               MCP’s to level 40H                                                        22:54:03

          22:58                               MCP’s to level 80H                                                        23:00:10

          23:02                               MCP’s to level 90H                                                        23:04:15

          23:06                               write parameters to memory

  293 18:52 (19 Oct 00)            enable transmission of ROI sci packet

                                                  Enable transmission of valid event by sector sci packet

          18:53                               Enable transmission of monitor hk packet

   322 16:51 (17 Nov 00)          uploaded LENA FSW V3.5 to CIDP 

          17:07                               uploaded LENA FSW V3.5 to CIDP 

          17:16                               uploaded LENA FSW V3.5 to CIDP 

          17:38                               instrument reset sent

          17:58                               HVPS unsafed

          18:04                               voltage threshold set to AA AA 74 74 51

          18:05                               current threshold set to FFx5

          18:07                               MCP’s to level 0

          18:13                               set overcount threshold to 000C

          18:15                               MCP’s enabled                                                               18:15:24

          18:19                               MCP’s to level 40H                                                        18:19:30

          18:24                               MCP’s to level 80H                                                        18:25:38

          18:28                               voltage threshold set to D5 D5 91 91 73

          18:33                               MCP’s to level A0                                                          18:33:48

          18:36                               start CFDs to level 11

          18:39                               current threshold set to  82 76 FF C0 6E

          18:42                               optics enabled                                                                 18:44:02

          18:47                               optics to level 20H                                                          18:48:07

          18:50                               optics to level 40H                                                          18:52:13

          18:55                               optics to level 50H                                                          18:56:18

          19:03                               optics to level 60H                                                          19:04:29

          19:07                               voltage threshold set to D5 D5 91 91 97

          19:11                               optics to level 70H                                                          19:12:40

          19:15                               optics to level 78H                                                          19:16:45

          19:28                               collimator enabled                                                          19:29:01

          19:33                               saved MCP stop supply state

   335 20:55 (30 Nov 00)           write parameters to memory

                                                  write parameters to memory

          20:56                               write parameters to memory

   339 00:44 (4 Dec 00)             enabled steering control scanning

                                                  enabled stop MCP overcount auto restore

          14:12                               disabled LENA autonomous capabilities

   341 22:33 (6 Dec 00)             enabled stop MCP overcount auto restore

          22:38                               set overcount threshold to 0009

   342 19:48 (7 Dec 00)             reset error flags

   348 23:19 (13 Dec 00)          HVPS unsafed

          23:31                              voltage threshold set to AA AA 74 74 51

          23:33                              current threshold set to FFx5

          23:35                              MCP’s to level 0

          23:43                              set overcount threshold to 0009

          23:54                              MCP’s enabled                                                                23:55:11

          23:57                              MCP’s to level 40H                                                         23:59:17

   349 00:10 (14 Dec 00)          MCP’s to level 80H                                                         00:11:33

          00:15                              voltage threshold to D5 D5 91 91 73

          00:16                              MCP’s to level A0                                                           00:17:41

          00:16                              MCP’s to level 90H                                                         00:17:41

          00:32                              optics enabled                                                                  00:34:03

          00:39                              optics to level 20H                                                           00:40:12

          00:49                              optics to level 40H                                                           00:50:25

          00:56                              optics to level 50H                                                           00:56:33

          00:59                              optics to level 60H                                                           01:00:39

          01:01                              voltage threshold to D5 D5 91 91 97

          01:04                              optics to level 70H                                                           01:04:44

          01:10                              optics to level 78H                                                           01:10:53

                                                 collimators enabled

          01:11                              saved MCP stop supply state

          01:29                              write parameters to memory     

          01:31                              write parameters to memory                                    

          01:33                              write parameters to memory                                    

   011 23:51 (11 Jan 01)           instrument on                                                                   23:54:45

   012 00:07 (12 Jan 01)           HVPS unsafed

          00:19                              voltage threshold to AA AA 74 74 51

          00:20                              current threshold to FFx5

          00:21                              MCP’s to level 0

          00:32                              set overcount threshold to 0009 (75 kHz)

          00:36                              MCP’s enabled

          00:37                              MCP’s to level 40H                                                         00:39:32

          00:49                              MCP’s to level 80H                                                         00:51:48

          00:50                              voltage threshold to D5 D5 91 91 73

          00:56                              MCP’s to level A0                                                           00:57:57

                                                 MCP’s to level 90

          01:08                              start CFDs to level 11

          01:09                              current threshold to 82 76 FF C0 6E

          01:09                              optics enabled                                                                  01:12:17

          01:18                              optics to level 20H                                                          01:20:28

          01:23                              optics to level 40H                                                           01:26:36

          01:30                              optics to level 50H                                                           01:32:44

          01:34                              optics to level 60H                                                           01:36:50

          01:35                              voltage threshold to D5 D4 91 91 97

          01:41                              optics to level 70H                                                           01:42:58

          01:46                              optics to level 78H

          01:56                              optics enabled                                                                  01:57:18

                                                 optics to level 20H

          02:01                              optics to level 40H                                                          02:03:26

          02:05                              optics to level 50H                                                          02:07:32

          02:09                              optics to level 60H                                                          02:11:37

          02:13                              optics to level 70H                                                          02:15:43

          02:20                              collimator enabled                                                           02:21:51

                                                 saved MCP stop supply state

          02:35                              write parameters to memory

          02:37                              write parameters to memory

          02:37                              write parameters to memory

         02:38                               enapled stop MCP overcount auto restore

 016  19:48 (16 Jan 01)            defined start of TOF to 26

         19:49                               defined start of TOF to 30

                                                 defined start of TOF to 64

         19:50                               defined start of TOF to 0FA

         19:54                               defined ROI  Region is 252 - 260 (3F*4 start bin,

                                                 width =8, all energy, polar & spin sectors).

         19:56                               enabled ROI packets 00

         22:05                               defined start of TOF to 30

                                                 defined start of TOF to 64

         22:06                               defined start of TOF to 26

                                                 defined start of TOF to 30

         22:07                               defined stop of TOF to OFA

 023  20:41 (23 Jan 01)            uploaded LENA FSW V3.6 to CIDP (no-reply)

         20:55                               uploaded LENA FSW V3.6 to CIDP 

         21:25                               instrument reset sent

         21:47                               HVPS unsafed

         21:49                               voltage threshold to AA AA 74 74 51

         21:50                               MCP’s to level 0

         21:51                               set overcount threshold to 0009

         21:55                               MCP’s enabled                                                                21:55:53

                                                 MCP’s to level 40H                 

         22:01                               MCP’s to level 80H                                                         22:02:02

                                                 voltage threshold to D5 D5 91 91 73

         22:05                               MCP’s to level A0                                                           22:06:07

                                                 MCP’s to level 90H

         22:09                               optics enabled                                                                  22:10:13

         22:13                               optics to level 20H                                                           22:14:19

         22:17                               optics to level 40H                                                           22:18:24

         22:21                               optics to level 50H                                                           22:22:30

         22:26                               optics to level 60H                                                           22:26:35

                                                 voltage threshold to D5 D5 91 91 97

         22:32                               optics to level 70H                                                           22:32:44

         22:36                               optics to level 78H                                                           22:36:49

         22:41                               collimators enabled (neg)                                                22:40:55

                                                 saved MCP stop supply state

                                               defined ROI

                                               enabled ROI packets 1

                                               enabled stop MCP overcount auto restore

   024 20:53 (24 Jan 01)         MCP’s to level 80H

          21:01                            reset error flags

   025 16:04 (25 Jan 01)         MCP’s to level 80H

   026 18:04 (26 Jan 01)         write parameters to memory

          18:05                            reset error flags

   040 20:45 (9 Feb 01)          write parameters to memory

         20:46                             write parameters to memory

   046 19:41 (15 Feb 01)        write parameters to memory

          19:42                            write parameters to memory

          19:43                            reset error flags

   068 03:15  (12 Mar 01)       write parameters to memory A9DD

          03:16                            write parameters to memory A9DF

          03:17                             reset error flags

 

“ISN MODE” TEST  

   316 01:37:28 (12 Nov 01)  Disable steering supply scan

          01:37:28                       Steering scan table is defined by array P[15] – P[0].  Steering                                                 

                                               supply steps through 1 command P[n] per spin.

          01:37:28                       Enable steering supply scan

          05:37:28                       Disable steering supply scan

 

Leonids “Chicken Mode”  

  322  04:00:00 (18 Nov 01)   Reset error flags

          04:00:00                       Disable auto restore

          04:00:00                       Disable collimators

          23:59:00                       Enable auto restore

 

326    02:55 – 16:03 (22 Nov 01)                

                                              Unrecoverable Data loss due to loss of command link to the                 

                                              spacecraft during MMM overwrite fix procedure

 

 361  (27 Dec 01)                   Spin-phase freewheeling anomaly

                                               corrected 22:34, 28 Dec 01

 

233      19:42:43 (21 Aug 02)  MCP Start HVPS to level A0H

233      19:43:31                       MCP Stop HVPS to level 90H

233   19:44:17                       Enable LENA Stop MCP HVPS auto-restore

 

  241   13:50:01 (29 Aug 02)   defined start TOF to 10H

 

311   14:18:00 (7 Nov 02)    Lena Reset   

14:42:00                       max HVPS outputs are limited to 100% of F.S.

14:44:00                       voltage threshold to AA AA 74 74 51

14:47:00                       MCP’s to level 0

 

14:49:00                       Set start and stop rate overcount threshold to p=09  

14:52:00                       MCP’s enabled

14:53:00                       MCP start to level 40H

14:54:00                       MCP stop to level 40H

14:59:00                       MCP start to level 80H

14:59:00                       MCP stop to level 80H

15:00:00                       voltage threshold to D5 D5 91 91 73

15:02:00                       optics enabled

15:03:00                       optics to level 20H

15:07:00                       optics to level 40H

 

312    05:33:00  (8 Nov 02)    MCP start to level A0H

05:34:00                        MCP stop to level 90H

05:35:00                        optics to level 50H

05:46:00                        voltage threshold to D5 D5 91 91 97

05:46:00                        collimator enabled                                                          

05:50:00                        optics to level 70H

           06:00:00                        Define TOF, Polar, and Energy bin ranges for

                                                 Region-of-interest

           06:01:00                        Enable transmission of selected ROI segment (ROISEG =1)

06:02:00                        saved MCP stop supply state

06:03:00                        Enable LENA Stop MCP hvps auto-restore

 

                                      Instrument reset sent

                                                 HVPS unsafed

           14:44:00                        voltage threshold to AA AA 74 74 51

                                      Set overcurrent thresholds for hvp supplies FF FF FF

  

   Leonids “Chicken Mode”   

  323  00:04:00  (19 Nov 02)  Disable auto restore

          00:08:00                       Disable collimators

          00:33:00                        start CFD to level 10H

          16:00:00                       Enable auto restore

 

140    17:53:00  (20 May 03)  Set Overcurrent Thresholds for HV Power Supply:

                                                    MCP start threshold to level 82H

                                                    MCP stop threshold to level 76H

                                                    Collimator Pos threshold to level FFH

                                                    Collimator Neg threshold to level C0H

                                                    Optics threshold to level 6EH RT

                                                MCP start to level B4H RT

                                                MCP stop to level 99H RT

 

 

143  17:17:00  (23 May 03)        Disable LENA auto-restore
        17:18:00                              MCP start voltage level B4H RT
        17:18:00                              MCP stop voltage level 99H RT
        17:21:00                              Save as new FSW defaults
        17:22:00                              Re-enable auto-restore

Note: The value for the MSTP changed to 99 but the MSTR remained with a value of AC.

 

 

* Lena Time (UT) indicates the time as observed by LENA, deduced from summary plot data  

   dumps, beginning 1 May 00